Skip to main content
CityRuleLookup

Naperville, IL Fire Regulations: Smoke Detectors (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Applies to
1- and 2-family homes, townhouses
Trigger
Renovation or addition to home
Unaffected areas
Existing alarms may stay battery-powered
Townhouses (3+ units)
Monitored fire alarm system required

Summary

Naperville's residential code amendment requires code-compliant smoke alarms in any area affected by a renovation or addition, while alarms in untouched portions of the home may remain battery-powered.

R310 Smoke Alarms: Add a new section to read as follows:

R310.6 Exception 2 Smoke Alarms, Power Source: Modify section to read as follows:

Smoke alarms in the portion of the residence that is not impacted by the renovation or addition installed in accordance with Section R314.2.2 shall be permitted to be battery powered. Smoke alarms within the area of renovation or addition shall follow power source requirements as identified in R310.6.

Add new subsections to read as follows:

R310.8 Fire Alarm And Detection Systems

Fire alarm and detection systems for townhouses shall be installed in multiple single-family dwellings (townhouses), if the building or structure contains three (3) or more units. All fire alarm and detection systems shall be listed and installed in accordance with the provisions of NFPA 72, the IBC 2024, the IFC 2024, and the current edition of the Naperville fire department's regulations for the installation, maintenance, and testing of fire alarm systems, as amended from time to time.

R311.1 Carbon monoxide alarms: Change to read as follows:

For new construction, an approved carbon monoxide alarm shall be installed outside and within 15 feet of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 101).

Full Breakdown

Under the city's amendments to the 2024 International Residential Code, smoke alarms installed within the portion of a home undergoing a renovation or addition must meet the power-source requirements of IRC Section R310.6; existing alarms in the unaffected portion of the residence may stay battery-powered. Townhouses with three or more units must also have fire alarm and detection systems installed and maintained under NFPA 72, the IBC, IFC, and Naperville Fire Department regulations. The rules apply to one- and two-family dwellings and townhouses citywide in Naperville, DuPage County, Illinois.

Violations & Fines

Enforced through the building permit and inspection process; a renovation or addition that doesn't bring smoke alarms into compliance can fail final inspection, delaying occupancy or permit closeout.

Frequently Asked Questions

Do I need hardwired smoke alarms for a home addition in Naperville?
Yes: smoke alarms in the portion of the home affected by the addition must meet IRC Section R310.6 power-source requirements; alarms elsewhere in the house can remain battery-powered.
Are smoke alarm rules different for townhouses?
Yes. Naperville requires townhouses with three or more units to have fire alarm and detection systems installed and monitored under NFPA 72 and the city fire department's regulations.

Sources & Official References

Other rules in Naperville

All Naperville rules

Compare Naperville to another location·View the Illinois fire regulations overview

Get notified when Smoke Detectors in Naperville, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.