Kenner, LA Hurricane Preparedness: Flood Elevation (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Equipment freeboard
2 feet above base flood elevation
New addition floor
2 feet above base flood elevation, all HVAC
Certification required
Registered engineer, architect, or land surveyor
Applies in
Zones AE, VE and local flood hazard zones
Max penalty
$500 fine, 60 days jail, Sec. 1-9

Summary

In flood hazard areas across Kenner, new construction and substantial improvements must meet the elevation standards of Code of Ordinances Sec. 5-182: mechanical, electrical, and HVAC equipment, and the lowest floor of new horizontal additions, must sit at least two feet above the base flood elevation to keep systems safe from storm flooding.

In all areas of special flood hazards (zone AE and VE) and areas of local flood hazard (zone X, X-Protected by Levee, and 0.2% Annual Chance), the following higher regulatory provisions for permits are required for all new construction and substantial damage/improvement (as further denied below) to ensure sites are reasonably safe from flooding. ... (4)Electrical, heating, ventilation, plumbing, air conditioning equipment and other service facilities shall be designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding, such facilities shall be located a minimum of two (2) feet above the base flood elevation.(5)All new horizontal additions must have the lowest floor and all HVAC shall be located a minimum of two (2) feet above the base flood elevation.

Full Breakdown

Sec. 5-182 sets the elevation standards that apply in both the special flood hazard areas, zones AE and VE, and the local flood hazard zones X, X-Protected by Levee, and 0.2% Annual Chance, for all new construction and substantial damage or improvement. A registered professional engineer, architect, or land surveyor must certify to the Department of Inspection and Code Enforcement that a project meets the standard. Beyond the general anchoring and flood-resistant-materials rules that apply chapterwide, Sec. 5-182 raises the bar for building systems specifically: electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities must be designed or located so water cannot enter or accumulate in them during flooding, and must sit at least two feet above the base flood elevation. Any new horizontal addition must have its lowest floor and all HVAC equipment at that same two-foot freeboard above the base flood elevation.

The floodplain administrator, working with the Department of Inspection and Code Enforcement, reviews and certifies compliance under Sec. 5-171, and can require additional base flood elevation data when FEMA has not supplied it for a site. Because Kenner sits low relative to Lake Pontchartrain and the Mississippi River levee system, this two-foot equipment and addition freeboard is meant to keep home systems functioning through the storm surge flooding a hurricane can push into the city.

Violations & Fines

Sec. 5-195 punishes any owner, contractor, architect, or other person who violates the elevation standards, or who maintains a building where the violation exists, as provided in Sec. 1-9: a fine of up to five hundred dollars, up to sixty days in jail, or both, with each day the violation continues treated as a separate offense.

Frequently Asked Questions

How high above flood level must my HVAC unit sit in Kenner?
Sec. 5-182 requires electrical, heating, plumbing, and air conditioning equipment in new construction or a substantial improvement to be designed or located at least two feet above the base flood elevation, so floodwater cannot enter or accumulate in the equipment during a storm.
Does a new room addition need to meet a flood elevation standard?
Yes. Sec. 5-182 requires any new horizontal addition to have its lowest floor and all HVAC equipment located at least two feet above the base flood elevation, the same freeboard required for mechanical and electrical equipment elsewhere in the chapter.
Who has to certify that my project meets the elevation standard?
Sec. 5-182 requires a registered professional engineer, architect, or land surveyor to submit a certification to the Department of Inspection and Code Enforcement confirming the project satisfies the chapter's elevation standard before the department signs off. That certification is kept with the permit file as part of the city's floodplain compliance record.

Sources & Official References

Other rules in Kenner

All Kenner rules

Compare Kenner to another location·View the Louisiana hurricane preparedness overview

Get notified when Flood Elevation in Kenner, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.