Skip to main content
CityRuleLookup

Kenner, LA Hurricane Preparedness: Roof Standards (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Adopting ordinance
Ord. No. 9425 (1-4-2007)
Amended section
IRC 2006 Section R301.2.1
Added references
ACI, IBHS, FASH high-wind guides
Base code
2006 International Residential Code
Enforcement
Dept. of Inspections and Code Enforcement

Summary

The City of Kenner amended the 2006 International Residential Code's wind design-criteria section, R301.2.1, to require residential construction to follow high-wind-area guides from the American Concrete Institute, the Institute for Business & Home Safety and the Federal Alliance for Safe Homes.

In addition, section 2 of Ord. No. 9425, adopted Jan. 4, 2007, adopted the following codes, known as the State Uniform Construction Code, which are annexed hereto as exhibits "A" through "G" are hereby adopted by reference as if they were copied fully herein, and shall govern all manner of construction hereafter undertaken within the City of Kenner: ... ... 3. International Residential Code for One and Two Family Dwellings, 2006 Edition, not including Chapter 1—Administration, V—Mechanical, VII—Plumbing and VIII—Electrical (Exh. "C") Chapter 3 of the International Residential Code for One and Two Family Dwellings, 2006 Edition, Section R301.2.1 (Design Criteria) shall be amended to include the following: a) The American Concrete Institute, Guide to Concrete Masonary Residential Construction in High Wind Areas b) Institute for Business & Home Safety c) Federal Alliance for Safe Homes

Full Breakdown

Ord. No. 9425, adopted January 4, 2007 and codified in the footnote to Chapter 5, adopted the State Uniform Construction Code for the City of Kenner, incorporating the 2006 editions of the International Building Code, International Existing Building Code and International Residential Code for One and Two Family Dwellings, each with certain administrative or trade chapters excluded because the city administers those functions itself. Within that adoption, Kenner specifically amended Chapter 3 of the International Residential Code, Section R301.2.1 (Design Criteria), the section that sets a home's structural design loads including wind, to add three named references: the American Concrete Institute's Guide to Concrete Masonry Residential Construction in High Wind Areas, the Institute for Business & Home Safety, and the Federal Alliance for Safe Homes.

Because R301.2.1 governs the wind-load design that dictates how a roof structure, its coverings and its connections to the walls below must be built to resist hurricane-force wind, incorporating these high-wind references means new and altered one- and two-family homes in the City of Kenner must be designed and permitted against high-wind construction guidance, not just the base 2006 IRC wind provisions. The amendment applies through the same Chapter 5 building-permit process enforced by the Department of Inspections and Code Enforcement.

Violations & Fines

Roof and structural work that does not meet the amended Section R301.2.1 design criteria cannot receive a building permit or pass inspection under Chapter 5's adoption of the State Uniform Construction Code, and constructing or altering a structure without the required permit is separately punishable as a misdemeanor under Sec. 5-80, with a minimum fine of $250.00 for a first conviction.

Frequently Asked Questions

Does Kenner require hurricane-resistant roof construction?
Kenner amended Section R301.2.1 of the 2006 International Residential Code, the design-criteria section that sets wind loads for one- and two-family homes, to add the American Concrete Institute's high-wind guide, the Institute for Business & Home Safety and the Federal Alliance for Safe Homes as required references.
What building code edition governs roof construction in Kenner?
The City of Kenner adopted the 2006 International Residential Code for One and Two Family Dwellings through Ord. No. 9425, with its own amendment to the Section R301.2.1 design criteria adding high-wind-area construction guidance for residential structures including their roofs.
Who enforces Kenner's building and roof construction standards?
The Department of Inspections and Code Enforcement administers the State Uniform Construction Code adopted under Chapter 5, including the amended wind design criteria, and Sec. 5-80 lets the department prosecute any construction performed without the required building permit as a misdemeanor offense.

Sources & Official References

Other rules in Kenner

All Kenner rules

Compare Kenner to another location·View the Louisiana hurricane preparedness overview

Get notified when Roof Standards in Kenner, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.