Key Facts

Trigger
New construction with fuel-fired appliance
Placement
Within 15 feet of sleeping area
Also required for
Homes with attached garage
Renovation exception
Unaffected areas may stay battery-powered

Summary

New construction in Naperville must include a carbon monoxide alarm within 15 feet of every sleeping area in homes with fuel-fired appliances or an attached garage, under the city's amended residential code.

R311.1 Carbon monoxide alarms: Change to read as follows:

For new construction, an approved carbon monoxide alarm shall be installed outside and within 15 feet of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages.

R311.4 Single And Multiple Station Carbon Monoxide Detectors: All carbon monoxide detectors shall be installed in accordance with the provisions of manufacturer's installation instructions.

R311.6 Exception 2 Carbon Monoxide Alarms, Power Source: Modify section to read as follows:

Carbon monoxide alarms installed in the portion of the residence that is not impacted by the renovation or addition installed in accordance with Section R311.2.2 shall be permitted to be battery powered. Carbon monoxide alarms within the area of renovation or addition shall follow power source requirements as identified in R311.6.

R313.1 Minimum Height: Add Exception 5.

Exception 5. Habitable spaces created in existing basements shall have ceiling heights of not less than 6 feet 8 inches, except that the ceiling height at obstructions shall be not less than 6 feet 4 inches from the basement floor.

Existing finished ceiling heights in non-habitable spaces in basement shall not be reduced.

Add new subsections to read as follows:

R314.8.1 Non-Monitored Fire Alarm Systems:

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 101).

Full Breakdown

Naperville's amendment to IRC Section R311.1 requires an approved carbon monoxide alarm installed outside and within 15 feet of each separate sleeping area for new construction in dwelling units with fuel-fired appliances (such as a gas furnace or water heater) or an attached garage. As with smoke alarms, CO alarms in portions of a home unaffected by a renovation or addition may remain battery-powered, while alarms in the affected area must meet the code's power-source requirements. This applies citywide in Naperville, DuPage County, Illinois.

Violations & Fines

Compliance is checked during the building permit and inspection process for new construction and qualifying renovations; missing or misplaced CO alarms can hold up final inspection sign-off.

Frequently Asked Questions

Does my new Naperville home need a carbon monoxide alarm?
Yes, if it has a fuel-fired appliance or an attached garage: an approved CO alarm must sit within 15 feet of each sleeping area under IRC Section R311.1 as amended.
Can I use a battery-powered CO alarm in Naperville?
Only in portions of the home not affected by a renovation or addition; alarms in the renovated area must follow the code's specific power-source requirements.

Sources & Official References

Other rules in Naperville

All Naperville rules

Compare Naperville to another location·View the Illinois building safety overview

Get notified when Carbon Monoxide Detectors in Naperville, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.