Ogden, UT Building Safety: Carbon Monoxide Detectors (2026)
Key Facts
- Who must comply
- Occupancies with fuel-fired appliance or attached garage
- Detector placement
- Within 20 ft of bedroom door, or 40 ft in shared hallway
- Detector standard
- UL/CSA-listed, meets UL 2034 or later
- Civil penalty
- $50.00 per day after warning period
- Penalty suspension window
- Compliance shown within 30 days
- Enforcing officials
- Building official and fire chief (§ 12-17-6)
Summary
Ogden City requires a working carbon monoxide detector outside every sleeping area in any residential occupancy with a fuel-fired appliance or attached garage. Tampering with or removing a required detector is a separate offense, and violations carry a $50 civil penalty per day after a warning period.
12-17-4: CO DETECTOR INSTALLATION REQUIREMENTS: ... A. CO detector(s) shall be centrally located outside of each separate sleeping area in the immediate vicinity of the bedrooms or sleeping rooms. ... ... 1. Within a dwelling unit, on the ceiling or wall outside of each separate sleeping area within twenty feet (20') of any door leading to a bedroom or sleeping room; 2. Where sleeping units, or more than six (6) dwelling units, share a common hallway, on the ceiling or wall of the common hallway within forty feet (40') of any door leading to a dwelling unit or a sleeping unit
Full Breakdown
Ogden City Code § 12-17-3 makes every existing residential occupancy or dwelling with a fuel-fired appliance or an attached garage subject to the CO detector chapter. Owners must install and maintain the detectors, test and replace batteries, and immediately fix or replace defective units; for dwellings built before 2005, the occupant carries those same install, battery, and repair duties, while owners of post-2004 dwellings must meet the building code's CO detector requirements instead. Section 12-17-4 sets placement: a detector centrally located outside each separate sleeping area, on the ceiling or wall within 20 feet of any door leading to a bedroom, or within 40 feet in a shared hallway serving sleeping units or more than six dwelling units.
Detectors must be UL- or CSA-listed, meet UL 2034 (or later) standards, and follow manufacturer mounting instructions, avoiding dead-air spaces. If a hallway detector is found tampered with, it must be replaced with a hard-wired unit; one found missing a battery must be replaced with a tamperproof, sealed-battery model. Section 12-17-5 makes it unlawful to fail to install or maintain a required detector, or to remove, deface, or otherwise tamper with one, though normal repair or replacement by an owner, manager, tenant, or agent is not tampering.
The building official and fire chief enforce the chapter under § 12-17-6, with authority to inspect on a change of occupancy, during permitted construction or renovation review, when checking compliance with the good landlord incentive program, or whenever lawfully on the premises. 00 civil penalty, suspended if compliance is shown within 30 days of the citation; each day a violation continues is a separate offense, and the city may also seek injunction, mandamus, or judicial abatement.
Violations & Fines
Failing to install or maintain a required CO detector, or tampering with or removing one, is an infraction under Ogden City Code § 12-17-7, punishable per Title 1, Chapter 4, Article A. Owners or tenants who do not correct a cited violation within the warning period owe a $50.00 civil penalty per day, suspended only if compliance is shown within 30 days of the citation.
Frequently Asked Questions
Does Ogden City require carbon monoxide detectors in rentals?
Where must a CO detector be placed in Ogden City?
Is it illegal to remove a CO detector in Ogden City?
What is the fine for a CO detector violation in Ogden City?
Sources & Official References
Other rules in Ogden
Compare Ogden to another location·View the Utah building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.