Passaic, NJ Building Safety: Elevator Maintenance (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing standard
ANSI A17.1
Maintenance duty
Doors, flooring, safety devices kept hazard-free
Preventive maintenance
Required continuously, § 219-92
Suspension notice
Owner must post time/duration/reason
Retroactive mandates
Interlocks, brakes, mirrors under § 219-94

Summary

Passaic's Property Maintenance Code requires every elevator in the city to be maintained to ANSI A17.1 standards, with doors, flooring, safety devices and operating mechanisms kept in good working order and free of hazards. Elevator equipment must also receive ongoing preventive maintenance and inspection under the same ANSI standard.

§ 219-91. Elevators to be maintained. All elevators shall be maintained as to meet the standards established and set forth in ANSI A17.1. The elevator doors, flooring, safety devices and operating mechanisms shall be maintained in good working order and free of hazards. § 219-92. Preventive maintenance and inspections of elevators. All elevators and elevator equipment and accessory devices shall be provided with preventive maintenance and inspections as required in ANSI A17.1. § 219-93. Suspension of elevator service. Elevator service shall not be suspended except where unavoidable or where necessary to provide servicing or repairs, and then only for the minimum period of time necessary to effectuate such service or repairs.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: rev 4978046; v41 updated 2026-07-01; through 07-01-2026).

Full Breakdown

1, and its doors, flooring, safety devices, and operating mechanisms must stay in good working order and free of hazards. 1, an ongoing obligation, not a one-time fix. Section 219-93 governs downtime: elevator service may not be suspended except where unavoidable or necessary for servicing or repairs, and then only for the minimum time needed. If an owner has advance knowledge of a planned suspension, the owner must post notice advising occupants of the time, duration, and reason for the outage. The chapter also carries retroactive equipment mandates in § 219-94 for older buildings, including key-operated continuous-pressure emergency interlock release switches, electrically released spring-applied brakes on belt- and chain-driven freight machines, electrical machine limits on drum-winding machines, hoistway-door interlocks on passenger elevators, an audible emergency signal on unattended automatic-operation elevators, and a mirror inside every self-service elevator in a multiple dwelling so a person can view the car before entering.

Enforcement runs through the Housing Officer under the Property Maintenance Code's general inspection and violation provisions (§§ 219-147 through 219-155), which apply to elevator defects the same as any other maintenance violation.

Violations & Fines

Failure to keep an elevator maintained to ANSI A17.1, to provide required preventive maintenance and inspections, or to comply with the retroactive safety-device mandates of § 219-94 is a Property Maintenance Code violation subject to the general penalty and enforcement procedure in Chapter 219, including a written notice of violation from the Housing Officer and referral to Municipal Court for noncompliance.

Frequently Asked Questions

What standard must Passaic building elevators meet?
Section 219-91 requires every elevator to be maintained to meet ANSI A17.1, with doors, flooring, safety devices and operating mechanisms kept in good working order and free of hazards at all times.
Can a Passaic landlord shut down a building elevator for repairs?
Yes, under § 219-93, but only where unavoidable or necessary for servicing, for the minimum time needed, and the owner must post notice telling occupants the time, duration, and reason if the suspension is known in advance.
Do older Passaic buildings have to add modern elevator safety devices?
Yes. Section 219-94 retroactively requires key-operated continuous-pressure interlock switches, ANSI-compliant brakes on belt- and chain-driven freight machines, hoistway door interlocks, an emergency signal on unattended elevators, and a viewing mirror in every self-service car.

Sources & Official References

Other rules in Passaic

All Passaic rules

Compare Passaic to another location·View the New Jersey building safety overview

Get notified when Elevator Maintenance in Passaic, NJ changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.