Stonecrest, GA Building Safety: Building Inspections (2026)
Key Facts
- Building stages
- foundation, damproofing, pre-cladding, frame, final
- Access duty
- permit holder keeps work exposed
- Inspection request
- notify Building Official when ready
- Warrant option
- municipal court judge, if entry refused
- Re-inspection fee
- council fee schedule applies
Summary
Stonecrest's Building Official inspects every stage of permitted construction under Sec. 7-170, and work must stay accessible and exposed for inspection until approved. For buildings, the code sets out five required checkpoints, from foundation through final inspection, before the Community Development Department can sign off on occupancy.
(a)Generally. ... Construction or work for which a permit is required shall be subject to inspection by the Building Official and such construction or work shall remain accessible and exposed for inspection purposes until approved. ... (c)Required inspections. The Building Official, upon notification, shall make the inspections set forth as follows:(1)Building.a.Foundation and slab inspection. To be made after trenches are excavated, forms are erected, and reinforcement is installed but before concrete is put in place. The appropriate silt and erosion control measures must be in place and functional. ... d.Frame (rough) inspection. To be made after wiring, piping, chimneys, duct and vents to be concealed are in place and all fire blocking is in place this inspection occurs before any insulation or wall coverings are installed.e.Final inspection. To be made after the building or structure is completed in compliance with this Code prior to issuance of the certificate of occupancy.
Full Breakdown
Sec. 7-170(a) makes clear that construction or work for which a permit is required shall be subject to inspection by the Building Official and such construction or work shall remain accessible and exposed for inspection purposes until approved. Sec. 7-170(c)(1) lists the building-inspection stages: the foundation and slab inspection, made after trenches are excavated and reinforcement installed but before concrete is poured, with erosion control measures in place; the damproofing inspection before crawl space or basement walls are backfilled; the pre-cladding/sheathing inspection after roof and wall bracing go up but before exterior cladding is placed; the frame or rough inspection once wiring, piping, chimneys, ducts and fire blocking are in place but before insulation or wall coverings; and the final inspection once the building is complete and code-compliant, required before a certificate of occupancy issues under Sec.
7-143(b)(1). Electrical, plumbing, mechanical and gas systems carry their own parallel underground, rough-in and final inspection stages under Secs. 7-170(c)(2) through (5). Sec. 7-170(j) puts the duty on the permit holder to notify the Building Official when work is ready and to provide safe access for the inspection. Sec. 7-170(l) authorizes re-inspection fees under the council's fee schedule whenever a prior violation is not corrected, the job is not actually ready when inspection is requested, or covered work cannot be inspected. Sec. 7-171 lets the Building Official obtain an inspection warrant from a municipal court judge when consent to inspect is refused.
Violations & Fines
Covering or concealing work before the required inspection is approved, or otherwise blocking access under Sec. 7-170(a) and (j), can draw a re-inspection fee under Sec. 7-170(l) and, for repeated or uncorrected violations, a notice of violation and municipal court citation under Sec. 7-64, punishable by fine or imprisonment with each day treated separately.
Frequently Asked Questions
What are the required building inspection stages in Stonecrest?
Who has to keep the job site ready for a Stonecrest inspection?
What if a Stonecrest inspector is refused entry to inspect work?
Sources & Official References
Other rules in Stonecrest
Compare Stonecrest to another location·View the Georgia building safety overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.