Fire Sprinkler Requirements
Lee's Summit does not require automatic fire sprinklers in new one- and two-family homes or townhouses. City Code § 7-908 only obligates the builder to offer the buyer the option to install sprinklers at the buyer's own cost, and the IRC's own mandatory sprinkler subsections are separately deleted by §§ 7-909 and 7-910.
Lee's Summit Residential Fire Sprinkler Rule
Few RestrictionsLee's Summit, MO, Code of Ordinances § 7-908 (Ord. No. 8584, § 1, 3-19-2019)
Section R313 is hereby amended to read as follows: A builder of a one-and two family dwelling or townhouse shall offer to any purchaser, on or before the time of entering into the purchase contract the option, at the purchaser's cost, to install or equip fire sprinklers in the one- and two-family dwelling or townhouse. Notwithstanding any other provision of law to the contrary, no purchaser of ...
Childcare Center Rules
Lee's Summit requires a special use permit for any "day care, group" operation caring for five to ten people at once in most residential zoning districts, per UDO Section 6.840; the city licenses the permit to a named provider, caps hours to 6 a.m. to 6 p.m., and requires proof of a current state license before a permit issues.
Lee's Summit Group Day Care Zoning Rules
Significant RestrictionsLee's Summit, MO, Unified Development Ordinance § 6.840
Group day care is a special use in a residential structure occupied by a day care provider that cares for between five and ten persons for care for any part of a 24-hour day. The following requirements shall apply: A.The permit shall be issued to a particular provider. A change in the day care provider shall require another public hearing.B.All applicable state licensing requirements must be me...
Door Locking Hardware
New homes and qualifying remodels in Lee's Summit must fit exterior doors with a single-cylinder deadbolt meeting City Code Sec. 7-1408.4: a minimum one-inch throw, five-pin tumbler cylinder, twist-resistant hardened steel guard and ANSI Grade 2 rating. The Security Code also sets rules for frames, strike plates, hinges and entry viewers, enforced by the Building Official.
Lee's Summit Exterior Door Lock Standards
Some RestrictionsLee's Summit, MO, Code of Ordinances § 7-1408.4 (Security Code, Art. XIV)
Exterior doors shall be provided with a single cylinder deadbolt that has a minimum projection of one inch. The deadbolt shall penetrate at least three-fourths-inch into the strike receiving the projected bolt. The cylinder shall have a twist-resistant, tapered hardened steel cylinder guard. The cylinder shall have a minimum of five (5) pin tumblers, shall be connected to the inner portion of t...
Anti-Mansionization
In neighborhoods placed into a Neighborhood Stabilization Overlay, Lee's Summit caps a new single-family home at one and one-half times the average square footage of existing houses on the same block face, and limits ridge height to the average height of the block's most common story count. The Director reviews every plan before a building permit issues.
Lee's Summit Mansionization & Teardown Caps
Significant RestrictionsLee's Summit, MO, Unified Development Ordinance Sec. 5.480 (Neighborhood Stabilization Overlay Criteria and Specifications)
4.Height. Maximum building height shall be the average height, measured from the street grade to the highest point of the ridge line, of the most common single-family residential structure along the block frontage; i.e. if the most common structure is a single story, even though there may be several two storied structures along the block frontage, the average of the most common structure height...
Green Building Code
Lee's Summit regulates building energy efficiency through its own locally-drafted Energy Conservation Code, City Code §§ 7-800 to 7-805, which sets minimum R-values for walls, floors, roofs, ceilings and ducts in new residential and non-residential construction rather than adopting a national IECC by reference. The Building Official enforces the standards through the same Chapter 7 permit and inspection process.
Lee's Summit Energy Conservation Code
Some RestrictionsLee's Summit, MO, Code of Ordinances § 7-802 (Energy Conservation Code, Ord. No. 8584, § 1, 3-19-2019)
The minimum required R-value for each element of the building thermal envelope shall be in accordance with the following: A.Wall assemblies forming portions of a building envelope shall meet or exceed an R factor rating of R-13. This requirement does not apply to doors, windows, or other openings or approved penetrations nor does it apply to basement concrete walls when the basement is not fini...
Building Permits
Lee's Summit requires a permit before almost any construction, alteration, or system work on a building. Sec. 7-127 makes any owner or agent who wants to build, enlarge, alter, repair, move, demolish or change a building's occupancy, or touch its electrical, gas, mechanical, plumbing or elevator systems, apply to the Building Official first.
Lee's Summit Building Permit Requirement
Some RestrictionsLee's Summit, MO, Code of Ordinances § 7-127
Any owner or authorized agent who intends to construct, enlarge, alter, repair, move, demolish, or change the occupancy of a building or structure, or to erect, install, enlarge, alter, repair, remove, convert or replace any electrical, gas, mechanical, plumbing, or elevator system, the installation of which is regulated by this Code, or to cause any such work to be done, shall first make appli...
Electrical Permits
Lee's Summit has adopted the 2017 National Electrical Code as its local electrical code, and Sec. 7-127 requires a permit before any electrical system covered by that code is installed, altered or replaced. The city amends a handful of NEC sections for basements, countertops and service disconnects.
Lee's Summit Electrical Permit & NEC Code
Some RestrictionsLee's Summit, MO, Code of Ordinances § 7-300
The 2017 edition of the National Electrical Code as published by the National Fire Protection Association (NFPA No. 70-2017) is hereby adopted and incorporated in this chapter as fully as if set forth herein, excepting only such parts or portions thereof as are specifically added or amended as stated below.
Building Inspections
Lee's Summit's Building Official inspects permitted work at fixed stages, from footings to the final walkthrough, and nothing can be covered up before the required inspection clears it. Sec. 7-160 lists the specific inspections; Sec. 7-158 requires work to stay exposed and accessible until the Building Official approves it.
Lee's Summit Required Building Inspections
Some RestrictionsLee's Summit, MO, Code of Ordinances § 7-160
The Building Official, upon notification, shall make the inspections set forth in this Code and the policies and procedures for required inspections. A.Footing or foundation inspection. Footing and foundation inspections shall be made after excavations for footings are complete and any required reinforcing steel is in place. For concrete foundations, any required forms shall be in place before...