Kenner, LA Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Zone AE freeboard
- 2 feet above BFE, or 18 in. above street
- Zone VE standard
- Lowest structural member 2 feet above BFE
- Enclosure limit
- 299 sq ft max below BFE, breakaway walls
- Applies to
- New construction and substantial improvement, Sec. 5-183, 5-184
- Max penalty
- $500 fine, 60 days jail, Sec. 1-9
Summary
New residential construction in Kenner's flood hazard areas must meet the freeboard standard of Code of Ordinances Sec. 5-183: in zone AE, the lowest floor must sit at least two feet above the base flood elevation, eighteen inches above the street centerline, or at -3.5 NAVD 88, whichever is highest.
Permits issued for new construction of any residential structure, must have the required NAVD 88 elevation of the lowest floor or lowest horizontal portion of the structural member and the base flood elevation noted on the permit. ... (2)In zone AE the lowest floor shall be at the highest of:a.[Located at a] minimum of two (2) feet above the BFE on the FIRM; orb.Eighteen (18) inches above the centerline of the street; orc.-3.5 NAVD 88.
Full Breakdown
Sec. 5-183 sets the elevation a new residential structure's lowest floor must reach before the Department of Inspection and Code Enforcement will note the required NAVD 88 elevation and the base flood elevation on the building permit. In zones X, X-Protected by Levee, and 0.2% Annual Chance inside the hurricane storm damage risk reduction system, the lowest floor must be at the highest of eighteen inches above the centerline of the street or elevation -3.5 NAVD 88. In zone AE, the lowest floor must be at the highest of three benchmarks: a minimum of two feet above the base flood elevation shown on the FIRM, eighteen inches above the street centerline, or -3.5 NAVD 88. In zone VE, the code instead measures from the bottom of the lowest horizontal structural member, which must sit at least two feet above the base flood elevation on the FIRM, with any enclosed area below that line free of obstructions or built with breakaway walls totaling no more than two hundred ninety-nine square feet, and fill cannot be used for structural support.
Sec. 5-184 applies the same three benchmarks to a substantially damaged or substantially improved residential structure, rather than only new construction. The two-foot freeboard above the mapped base flood elevation is the city's higher regulatory standard, exceeding FEMA's minimum, and is meant to keep the living space of a new or rebuilt house above the water a base flood event would bring to the lot.
Violations & Fines
Sec. 5-195 punishes any owner, contractor, architect, or other person who builds below the required freeboard, or maintains a structure that does not meet it, as provided in Sec. 1-9: a fine of up to five hundred dollars, up to sixty days in jail, or both, with each day the violation continues counted as a separate offense.
Frequently Asked Questions
How much freeboard does a new house need above base flood elevation in Kenner?
Does the freeboard rule apply to rebuilding after storm damage?
What is different about the standard in zone VE?