Pico Rivera, CA Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Enforcing officer
Director of Public Works (floodplain administrator)
Elevation standard
Lower of AR base flood elevation or 3 ft above grade
Minimum elevation
Never less than 2 ft above highest adjacent grade
Certification required
By registered engineer or surveyor at completion
Venting alternative
1 sq in of opening per sq ft of enclosed area
Penalty
Misdemeanor under § 15.50.430

Summary

Under the City of Pico Rivera's floodplain ordinance, new residential construction in an AR flood zone must have its lowest floor elevated above the highest adjacent grade, capped at the lower of the AR base flood elevation or three feet, but never less than two feet.

Residential construction, shall have the lowest floor, including basement, in an AR zone, elevated above the highest adjacent grade to a height equal to the lower of either the AR base, flood elevation or the elevation that is three feet above the highest adjacent grade, but in no event shall be less than two feet above the highest adjacent grade. Upon the completion of the structure, the elevation of the lowest floor including basement shall be certified by a registered professional engineer or surveyor, and verified by the community building inspector to be properly elevated. Such certification or verification shall be provided to the floodplain administrator.

Full Breakdown

Pico Rivera Municipal Code § 15.50.525(C)(1) sets the city's elevation standard for construction inside its mapped flood hazard areas along the Rio Hondo and San Gabriel Rivers. For residential construction in an AR zone, the lowest floor, including any basement, must be elevated above the highest adjacent grade to a height equal to the lower of either the AR base flood elevation or the elevation that is three feet above the highest adjacent grade, but in no event less than two feet above the highest adjacent grade.

Once built, that elevation has to be proven: the same subsection requires the lowest-floor elevation to be certified by a registered professional engineer or surveyor and verified by the city's building inspector before the floodplain administrator, who under § 15.50.500 is the director of public works, signs off. Nonresidential buildings get an alternative under subsection (C)(2): instead of elevating, they may be floodproofed watertight below the same reference elevation, provided a licensed engineer or architect certifies the design resists hydrostatic and hydrodynamic loads. Section 15.50.525 also requires enclosed areas below the lowest floor used only for parking, access, or storage to have flood-vent openings totaling at least one square inch per square foot of enclosed area, with the lowest opening no higher than one foot above grade, so floodwater can enter and exit without pushing against the walls.

These elevation and floodproofing rules apply on top of, not instead of, the federal Flood Insurance Rate Map data that § 15.50.420 adopts as the basis for identifying which parcels are in a special flood hazard area.

Violations & Fines

Constructing, extending, or altering a structure without meeting the required elevation, floodproofing, or venting standard violates § 15.50.430, which the chapter itself declares a misdemeanor; the city may also treat noncompliant construction as a public nuisance subject to summary abatement under § 1.20.010. Any structure lacking the elevation certificate the floodplain administrator requires is presumed to be in violation under § 15.50.315 until documentation is produced.

Frequently Asked Questions

How high must a home be built above flood level in Pico Rivera?
In an AR flood zone, § 15.50.525(C)(1) requires the lowest floor to be elevated above the highest adjacent grade to whichever is lower: the AR base flood elevation or three feet above grade, but the elevation can never be less than two feet above the highest adjacent grade.
Who verifies that a building meets Pico Rivera's flood elevation requirement?
The city's floodplain administrator, who is the director of public works under § 15.50.500, must receive certification from a registered professional engineer or surveyor confirming the lowest floor's elevation, and the city's building inspector must verify the structure was properly elevated before it is signed off.
Can a commercial building be floodproofed instead of elevated?
Yes. Section 15.50.525(C)(2) lets nonresidential structures be floodproofed watertight below the applicable elevation instead of raised, but a registered engineer or architect must certify that the design resists floodwater's hydrostatic and hydrodynamic forces and that utilities are protected from flood damage.

Sources & Official References

Other rules in Pico Rivera

All Pico Rivera rules

California rules heatmap·Compare Pico Rivera to another location·View the California environmental rules overview

Get notified when Flood Elevation Requirements in Pico Rivera, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Los Angeles County handle flood elevation requirements.

West Covina, CA
Some Restrictions
Norwalk, CA
Some Restrictions
Carson, CA
Some Restrictions
South Gate, CA
Some Restrictions
Los Angeles, CA
Some Restrictions
Pasadena, CA
Some Restrictions
Palmdale, CA
Some Restrictions
Lakewood, CA
Some Restrictions