Key Facts

Freeboard standard
BFE plus 1.5 feet minimum
Accessory-structure exception
600 sq ft, one story, storage/parking only
Critical facility standard
BFE plus 3 feet or 500-yr flood
Substantial improvement trigger
50% of market value within 5 years
Enforcing officer
Floodplain Administrator
Elevation certificate fee
Charged by Engineering Department, § 9-19

Summary

Plantation requires new and substantially improved buildings in a special flood hazard area to be elevated to at least one and one-half feet above base flood elevation, the City's freeboard standard under Section 9-12(c)(1) of the Floodplain Management Ordinance. That exceeds the Florida Building Code's baseline requirement and applies on top of FEMA's mapped base flood elevation for the parcel.

Additional Elevation (Freeboard) Buildings: For buildings in special flood hazard areas, the minimum FBC elevation requirements shall be to or above the base flood elevation plus one and one-half (1.5) feet.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 30 Update 1).

Full Breakdown

5 feet, half a foot above the Florida Building Code's own minimum. 2, is anchored against flotation and lateral movement, is built of flood damage-resistant materials below base flood elevation plus one foot, and has its mechanical, plumbing and electrical systems elevated to that same plus-one-foot line. Enclosures below elevated buildings are flatly prohibited under Section 9-12(c)(2), including breakaway-wall enclosures. Fill placed to raise a building must meet the compaction standard of ASTM D-698 or the FBC's engineered-fill requirements under Section 9-12(c)(3). Critical facilities get the strictest standard: Section 9-12(c)(4) requires them to sit outside the special flood hazard area where a feasible alternative site exists, and if built inside it, they must be elevated to base flood elevation plus three feet or the 500-year flood elevation, whichever is higher, with flood-proofing to keep toxic substances out of floodwater.

Section 9-12(c)(5) defines a 'substantial improvement,' the trigger for full compliance, as repair or renovation work whose cumulative cost over any five-year period equals or exceeds 50 percent of the building's market value; a structure that already suffered 'substantial damage' is treated as a substantial improvement regardless of the repair's scope. The Engineering Department separately charges a fee for the elevation certificates owners use to support flood insurance applications under Section 9-19.

Violations & Fines

Any development in a special flood hazard area that skips a required permit, conflicts with an issued permit, or lacks documentation of the lowest floor's elevation is presumed to violate Chapter 9 under Section 9-9(a) until the owner supplies that documentation. The Floodplain Administrator can serve a notice of violation or a stop-work order under Section 9-9(b), and anyone who keeps working after being served, other than to fix the violation, faces the penalties prescribed by Section 9-9(c) and the Code generally.

Frequently Asked Questions

How much higher than base flood elevation must my house be built in Plantation?
At least one and one-half feet higher. Section 9-12(c)(1) of the Floodplain Management Ordinance sets that 1.5-foot freeboard for any building in a mapped special flood hazard area, on top of the base flood elevation shown on FEMA's Flood Insurance Rate Map for the parcel, a stricter standard than the Florida Building Code's own baseline minimum.
Can I build a shed below base flood elevation in Plantation?
Only a narrow accessory structure qualifies. Section 9-12(b) allows a one-story accessory building of 600 square feet or less used solely for parking or storage to sit below base flood elevation, provided it has FBC-compliant flood openings, is anchored against flotation, uses flood damage-resistant materials below base flood elevation plus one foot, and has its utilities elevated to that same line.
What happens if I can't document my home's elevation after a flood?
Section 9-9(a) presumes a building without documented lowest-floor elevation or other required compliance evidence to be in violation of the Floodplain Management Ordinance until that documentation is produced, and the Floodplain Administrator can issue a stop-work order or notice of violation under Section 9-9(b) while the record is incomplete.

Sources & Official References

Other rules in Plantation

All Plantation rules

Florida rules heatmap·Compare Plantation to another location·View the Florida environmental rules overview

Get notified when Flood Elevation Requirements in Plantation, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Flood Elevation Requirements in Nearby Cities

How other cities in Broward County handle flood elevation requirements.

Hollywood, FL
Some Restrictions
Pembroke Pines, FL
Some Restrictions
Fort Lauderdale, FL
Some Restrictions
Pompano Beach, FL
Significant Restrictions