Woodbury, MN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard
- 1 foot above regional (100-yr) flood elevation
- Fill extension
- 15 feet beyond structure
- Accessory floodproofing size cap
- 500 sq ft
- Automatic openings
- 1 sq in per sq ft of flooded area
- Opening height limit
- 1 foot above adjacent grade
Summary
Woodbury requires one foot of freeboard above the regional (100-year) flood elevation. City Code Sec. 25-6 sets the regulatory flood protection elevation at that level, and Sec. 25-20 requires new structures in the flood fringe district to have their lowest floor built up to it on extended fill.
The regulatory flood protection elevation shall be an elevation no lower than one foot above the elevation of the regional flood plus any increases in flood elevation caused by encroachments on the floodplain that result from designation of a floodway.... (a)All structures, including accessory structures, must be elevated on fill so that the lowest floor including basement floor is at or above the regulatory flood protection elevation. The finished fill elevation for structures shall be no lower than one foot below the regulatory flood protection elevation and the fill shall extend at such elevation at least 15 feet beyond the outside limits of the structure erected thereon.
Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 48).
Full Breakdown
Woodbury measures flood protection against a single benchmark: the regulatory flood protection elevation, defined in Sec. 25-6 as no lower than one foot above the elevation of the regional flood, plus any rise in flood elevation caused by floodway encroachments. That one-foot freeboard becomes a hard construction standard in the flood fringe district under Sec. 25-20(a): every structure, including accessory structures, must be elevated on fill so the lowest floor, including any basement floor, sits at or above the regulatory flood protection elevation, and the fill itself must be no lower than one foot below that elevation and extend at least 15 feet beyond the structure's outside limits.
Sec. 25-20(b) allows one narrow alternative for small accessory buildings: structures under 500 square feet that are not designed for human habitation may be dry-floodproofed to the FP-1 or FP-2 classification in the State Building Code instead of elevated on fill, or, for a detached garage used solely for parking and storage, to the FP-3 or FP-4 classification. Floodproofed structures must be anchored against flotation and lateral movement, have mechanical equipment elevated to or above the regulatory flood protection elevation, and include at least two automatic openings on two different exterior walls, sized to one square inch of opening per square foot of enclosed area subject to flooding, with the lowest opening no more than one foot above the adjacent grade; a garage door opened by hand does not satisfy this automatic-opening requirement.
Violations & Fines
A structure built with its lowest floor below the one-foot freeboard set by Sec. 25-6, or on fill that falls short of the 15-foot extension required by Sec. 25-20(a), fails Woodbury's compliance standard in Sec. 25-14 and cannot receive approval; a floodproofed accessory structure missing the automatic openings required by Sec. 25-20(b)(2)(iii) is likewise rejected at inspection.
Frequently Asked Questions
How much freeboard above the flood elevation does Woodbury require?
How high must a new home's lowest floor sit in the flood fringe district?
Can a small shed skip the elevation requirement?
What openings must floodproofed accessory structures have?