Woodbury, MN Environmental Rules: Flood Elevation Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Freeboard
1 foot above regional (100-yr) flood elevation
Fill extension
15 feet beyond structure
Accessory floodproofing size cap
500 sq ft
Automatic openings
1 sq in per sq ft of flooded area
Opening height limit
1 foot above adjacent grade

Summary

Woodbury requires one foot of freeboard above the regional (100-year) flood elevation. City Code Sec. 25-6 sets the regulatory flood protection elevation at that level, and Sec. 25-20 requires new structures in the flood fringe district to have their lowest floor built up to it on extended fill.

The regulatory flood protection elevation shall be an elevation no lower than one foot above the elevation of the regional flood plus any increases in flood elevation caused by encroachments on the floodplain that result from designation of a floodway.... (a)All structures, including accessory structures, must be elevated on fill so that the lowest floor including basement floor is at or above the regulatory flood protection elevation. The finished fill elevation for structures shall be no lower than one foot below the regulatory flood protection elevation and the fill shall extend at such elevation at least 15 feet beyond the outside limits of the structure erected thereon.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 48).

Full Breakdown

Woodbury measures flood protection against a single benchmark: the regulatory flood protection elevation, defined in Sec. 25-6 as no lower than one foot above the elevation of the regional flood, plus any rise in flood elevation caused by floodway encroachments. That one-foot freeboard becomes a hard construction standard in the flood fringe district under Sec. 25-20(a): every structure, including accessory structures, must be elevated on fill so the lowest floor, including any basement floor, sits at or above the regulatory flood protection elevation, and the fill itself must be no lower than one foot below that elevation and extend at least 15 feet beyond the structure's outside limits.

Sec. 25-20(b) allows one narrow alternative for small accessory buildings: structures under 500 square feet that are not designed for human habitation may be dry-floodproofed to the FP-1 or FP-2 classification in the State Building Code instead of elevated on fill, or, for a detached garage used solely for parking and storage, to the FP-3 or FP-4 classification. Floodproofed structures must be anchored against flotation and lateral movement, have mechanical equipment elevated to or above the regulatory flood protection elevation, and include at least two automatic openings on two different exterior walls, sized to one square inch of opening per square foot of enclosed area subject to flooding, with the lowest opening no more than one foot above the adjacent grade; a garage door opened by hand does not satisfy this automatic-opening requirement.

Violations & Fines

A structure built with its lowest floor below the one-foot freeboard set by Sec. 25-6, or on fill that falls short of the 15-foot extension required by Sec. 25-20(a), fails Woodbury's compliance standard in Sec. 25-14 and cannot receive approval; a floodproofed accessory structure missing the automatic openings required by Sec. 25-20(b)(2)(iii) is likewise rejected at inspection.

Frequently Asked Questions

How much freeboard above the flood elevation does Woodbury require?
Sec. 25-6 sets the regulatory flood protection elevation at not lower than one foot above the elevation of the regional (100-year) flood, plus any rise caused by floodway encroachments.
How high must a new home's lowest floor sit in the flood fringe district?
Sec. 25-20(a) requires the lowest floor, including the basement, to sit at or above the regulatory flood protection elevation, with fill extending at least 15 feet beyond the structure.
Can a small shed skip the elevation requirement?
Sec. 25-20(b) allows accessory structures under 500 square feet to be dry-floodproofed to FP-1 or FP-2 standards instead of elevated on fill, provided they are not used for human habitation.
What openings must floodproofed accessory structures have?
Sec. 25-20(b)(2)(iii) requires at least two automatic openings on two different walls, with a combined area of one square inch per square foot of flooded area, and the lowest opening no higher than one foot above grade.

Sources & Official References

Other rules in Woodbury

All Woodbury rules

Compare Woodbury to another location·View the Minnesota environmental rules overview

Get notified when Flood Elevation Requirements in Woodbury, MN changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.