Gulfport, FL Fence Regulations: Retaining Walls (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Material required
Concrete construction only
Minimum concrete strength
3,000 psi at 28 days
Minimum cap height
3.5 ft above mean high tide
Cap dimensions
12 in thick, 14 in wide minimum
Tie-back rod length
At least 18 feet
Governing article
Chapter 6, Article III

Summary

Gulfport's only retaining-wall standard sits in the seawall chapter: Sec. 6-38 requires seawalls, bulkheads and retaining walls to be concrete construction meeting detailed engineering minimums, including a 3,000 psi concrete strength and a cap elevation at least three and a half feet above mean high tide.

All seawalls, bulkheads and retaining walls constructed or altered shall be of concrete construction in compliance with the following minimum standards: (1)All seawalls and bulkheads shall be of concrete, utilizing the tongue and groove sheet pile type construction, with poured in place concrete cap and tie back anchors. The concrete shall have a minimum test strength of 3,000 psi at 28 days and all reinforcing steel shall be covered with a minimum of 2″ of concrete ... (a)The elevation of the top of the cap of all seawalls shall be a minimum of 3½ feet above mean high tide of the most adjacent tidal waters.(b)No structure or improvement for which a permit is required under this article shall be approved unless adequate provisions are made by applicant to safeguard such improvement or structure from materially interfering with flow of surface drainage water into the most adjacent tidal waters.

Full Breakdown

Sec. 6-38 governs every seawall, bulkhead and retaining wall built or altered in the city and requires concrete construction to specific minimum standards. Seawalls and bulkheads must use tongue-and-groove sheet-pile construction with a poured-in-place concrete cap and tie-back anchors; the concrete must test to at least 3,000 psi at 28 days, with reinforcing steel covered by at least two inches of concrete. Sheet piling must be at least five inches thick with vertical #4 deformed reinforcing bars spaced twelve inches on center and horizontal #3 bars spaced one foot on center.

The concrete cap must be at least twelve inches thick and fourteen inches wide, with slabs projecting at least three inches into it, and tie-back rods must be steel, spaced no more than twelve feet on center, at least eighteen feet long with a twelve-inch L-bend, and coated with an approved bitumastic compound unless the building inspector approves a shorter length. The top of every seawall cap must sit at least three and a half feet above mean high tide of the adjacent tidal waters, and no permitted structure may materially interfere with surface drainage flow into those waters.

These specifications trace to Ordinance No. 62-10 (1962) and were amended by Ordinance No. 77-15 (1977); a standard-specifications drawing referenced in Sec. 6-44 is on file with the city clerk and applies alongside the written minimums, including a ten-foot minimum slab length for walls facing the open expanse of Boca Ciega Bay.

Violations & Fines

Building or altering a seawall, bulkhead or retaining wall that does not meet the Sec. 6-38 concrete, reinforcement and elevation minimums is a violation of Chapter 6, Article III, penalized under Sec. 6-43 according to the general penalty at Sec. 1-6. The building inspector may also order repair or removal of any wall found hazardous to public safety within thirty days under Sec. 6-40, and failure to comply is itself a separate violation.

Frequently Asked Questions

What material must a retaining wall in Gulfport be built from?
Sec. 6-38 requires all seawalls, bulkheads and retaining walls to be of concrete construction meeting minimum engineering standards, including 3,000 psi concrete strength at 28 days and specified reinforcing steel placement; there is no separate allowance for other materials under this section.
How high must a Gulfport seawall cap be built?
Sec. 6-38(7)(a) sets the top of the cap of all seawalls at a minimum of three and a half feet above the mean high tide of the most adjacent tidal waters, so the required elevation depends on the tidal reading at each waterfront lot.
Does a retaining wall in Gulfport need a permit?
Yes. Sec. 6-35 requires a permit application to the building inspector, with plans generally sealed by a Florida-registered engineer, before any wall covered by Sec. 6-34 is built or altered, and the Sec. 6-38 construction standards apply once that permit issues.

Sources & Official References

Other rules in Gulfport

All Gulfport rules

Florida rules heatmap·Compare Gulfport to another location·View the Florida fence regulations overview

Get notified when Retaining Walls in Gulfport, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Retaining Walls in Nearby Cities

How other cities in Pinellas County handle retaining walls.

St. Petersburg, FL
Some Restrictions