Key Facts

Door thickness
1 3/4 in. solid-core minimum
Deadbolt projection
1 inch minimum
Cylinder spec
5-pin tumbler minimum
Strike embedment
3/4 inch minimum
Violation penalty
up to $500 or 6 months jail

Summary

Every exterior swinging door on a Montebello house or attached garage, including the door from the garage into the home, must have a solid-core wood door at least one and three-fourths inches thick and a single or double cylinder deadbolt with a one-inch bolt projection and a five-pin tumbler cylinder. Section 15.08.100 sets the specification, and violating the chapter is a misdemeanor.

A.Except for vehicular access doors, all exterior swinging doors of any residential building and attached garages, including the door leading from the garage area into the dwelling unit, shall be equipped as follows:1.All wood doors shall be of solid-core construction with a minimum thickness of one and three-fourths inches, or with panels not less than nine-sixteenths inch thick.2.A single or double door shall be equipped with a double or single cylinder deadbolt lock. ... The bolt shall have a minimum projection of one inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-fourths inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five-pin tumblers, and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth inch in diameter. ... B.Any person, firm, or corporation violating any of the provisions of this chapter is guilty of a misdemeanor and shall be punishable for each offense, by a fine of not more than five hundred dollars, or by confinement in jail for not more than six months, or by both fine and confinement in jail.

Full Breakdown

Chapter 15.08, the city's building security regulations added under Ordinance No. 2336 in 2010, sets these hardware standards apart from the general California Building Code. Section 15.08.100(A) covers every exterior swinging door of a residential building and its attached garage, requiring wood doors to be solid-core construction at least one and three-fourths inches thick, or with panels at least nine-sixteenths inch thick, and a single or double cylinder deadbolt lock with a bolt projection of at least one inch built to repel cutting-tool attack, an embedment of at least three-fourths inch into the strike, a cylinder guard, a minimum of five-pin tumblers, and connecting screws at least one-fourth inch in diameter.

The inactive leaf of a double door needs metal flush bolts embedded at least five-eighths inch into the door frame, and any glazing within forty inches of the lock must be fully tempered or burglary-resistant unless a double-cylinder deadbolt is used instead. The same section also requires street numbers at least four inches high in a contrasting color, visible to approaching emergency vehicles, plus illuminated diagrammatic directories and minimum lighting levels for multi-family complexes. The building official, or the code enforcement supervisor subject to the building division's approval, administers the chapter under Section 15.08.140, and no building permit may receive final approval or utility release until the applicant satisfies the enforcing authority that the hardware complies.

Violations & Fines

Building, occupying or maintaining a residential structure that fails to meet the Chapter 15.08 hardware specifications is a misdemeanor under Section 15.08.160(B), punishable for each offense by a fine of not more than five hundred dollars, confinement in jail for not more than six months, or both. The enforcing authority may also withhold a utility release or final permit approval under Section 15.08.140 until the required deadbolt, strike and door construction standards are met.

Frequently Asked Questions

What deadbolt spec does a Montebello house need?
Section 15.08.100(A)(2) requires a single or double cylinder deadbolt with at least a one-inch bolt projection, a three-fourths inch embedment into the strike, a cylinder guard, a minimum of five-pin tumblers, and connecting screws at least one-fourth inch in diameter, on every exterior swinging door of the home and its attached garage.
Does the garage-to-house door need this hardware too?
Yes. Section 15.08.100(A) specifically includes the door leading from the garage area into the dwelling unit among the exterior swinging doors that must meet the solid-core construction and deadbolt specifications.
What happens if my house doesn't meet the hardware rule?
It is a misdemeanor under Section 15.08.160(B), punishable by a fine of up to five hundred dollars, up to six months in jail, or both, and the building official can withhold a utility release or final permit approval under Section 15.08.140 until the hardware complies.
Who enforces these door hardware requirements?
The building official, or the code enforcement supervisor subject to the building division's approval, administers Chapter 15.08 under Section 15.08.140, and reviews compliance before any building permit tied to the work receives final approval.

Sources & Official References

Other rules in Montebello

All Montebello rules

California rules heatmap·Compare Montebello to another location·View the California building safety overview

Get notified when Door Locking Hardware in Montebello, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Door Locking Hardware in Nearby Cities

How other cities in Los Angeles County handle door locking hardware.

Los Angeles, CA
Some Restrictions
Lancaster, CA
Some Restrictions
Palmdale, CA
Some Restrictions
Long Beach, CA
Some Restrictions
Glendale, CA
Some Restrictions