Kenner, LA Building Safety: Elevator Maintenance (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

High-rise threshold
Over 35 feet in height
Vestibule door rating
Minimum one-hour fire resistance
Hoistway venting
Cannot vent through machine room
Communication requirement
24-hour two-way system per elevator
Penalty
$200 per day of violation
Exemption
Single-family dwellings excluded

Summary

Kenner Code § 8-2(C)(6) sets fire-safety construction standards for elevators in every high-rise building, defined as any structure over 35 feet tall. Elevator lobbies must sit behind one-hour fire-rated vestibule doors, hoistways cannot vent through machine rooms, and every elevator needs on-site keys plus a 24-hour two-way emergency communication line tied to fire department controls.

(6)Elevators.(a)All elevators and elevator lobbies shall comply with the following: ... 1.Except for the main entrance level, all elevators on all floors shall open into elevator lobbies which are separated from the remainder of the building by a vestibule. Doors to the vestibule shall be labeled and listed and shall have a minimum of one-hour fire-resistive rating and shall have closing devices ... 6.Keys are to be provided at each elevator location and in the central fire control room for all elevators in the building. All elevators are to be provided with two-way communication systems connected to an approved emergency service which operates on a twenty-four-hour basis. All elevators are to be equipped with fire department control mechanisms. ... (E)(3)Any person, firm, corporation, etc., who does not comply with the provisions of this section shall be found in violation of this section. A violation shall carry a fine of two hundred dollars ($200.00) per day and each day constitutes a separate violation. ... (5)Single-family dwellings are excluded from this section.

Full Breakdown

Kenner Code of Ordinances § 8-2 requires early warning smoke detection, alarm systems, and automatic sprinklers in every high-rise building in the city, defined in subsection (B) as any structure exceeding thirty-five feet in height, including roof-level mechanical rooms and penthouses. Subsection (C)(6) adds elevator-specific construction rules for those buildings. Except at the main entrance level, every elevator must open into a lobby separated from the rest of the floor by a vestibule whose doors carry at least a one-hour fire-resistive rating, automatic closing devices, and a drop sill to limit air leakage; those doors must close automatically once a smoke detector on the lobby ceiling activates, sending all cars serving that lobby back to the main floor under manual control only.

Elevator hoistways cannot be vented through the elevator machine room; cable slots entering that room must be sleeved beneath the floor and extend at least twelve inches below the shaft vent so smoke cannot pass through into the machine room. Every elevator location, plus the building's central fire control room, must keep a set of elevator keys on hand, and every elevator needs a two-way communication system tied to an emergency service operating twenty-four hours a day, along with fire department control mechanisms. The City of Kenner Department of Regulatory Inspections and the Kenner Fire Department inspect for compliance, the rule applies only to buildings built after the ordinance's effective date, and single-family dwellings are excluded under subsection (E). A violation carries a $200-per-day fine, with each day counted as a separate offense.

Violations & Fines

Skipping the one-hour fire-rated vestibule doors, the smoke-detector elevator recall system, or the sleeved hoistway venting required by Section 8-2(C)(6) is a violation, as is failing to keep elevator keys on-site or omitting the required 24-hour two-way communication system. Subsection (E)(3) sets the penalty at $200 per day, with each day of noncompliance a separate offense, though single-family dwellings are excluded from the whole section.

Frequently Asked Questions

What counts as a high-rise building under Kenner's fire code?
Section 8-2(B) defines a high-rise building as any structure that exceeds thirty-five feet in height, measured from the first floor slab to the top of the roof slab or deck, and the definition includes roof-level mechanical equipment rooms and penthouses, though it excludes elevator, stair, and other unoccupied shaft spaces from the height measurement.
Do elevator lobbies need special fire-rated doors?
Yes. Section 8-2(C)(6)(1) requires vestibule doors separating elevator lobbies from the rest of the floor to carry at least a one-hour fire-resistive rating, have automatic closing devices, and include a drop sill, and those doors must close automatically once a lobby smoke detector is triggered.
What is the penalty for an out-of-compliance high-rise elevator?
Section 8-2(E)(3) sets the penalty at a $200 fine per day, with each day of noncompliance treated as a separate violation, though the requirement applies only to buildings built after the ordinance took effect and single-family dwellings are excluded under subsection (E)(5).

Sources & Official References

Other rules in Kenner

All Kenner rules

Compare Kenner to another location·View the Louisiana building safety overview

Get notified when Elevator Maintenance in Kenner, LA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.