Skokie, IL Building Safety: Elevator Maintenance (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Inspection frequency
at least every 6 months
Maintenance standard adopted
ASME A17.3-90
Certificate posting
required inside each elevator
New equipment
barred from use until first inspection passes
Pre-2005 elevators
must meet ASME A17.3 standby/alarm rules

Summary

Skokie requires every elevator, escalator, dumbwaiter and movable stage or orchestra floor in the Village to be inspected under the Village Manager's direction at least once every six months, with unsafe equipment ordered stopped until it is brought back into compliance.

Add 3001.5.2 Inspections. Every elevator, movable stage, movable orchestra floor, movable platform, dumbwaiter or escalator shall be inspected under the direction of the Village Manager or designee at least once every 6 months, and no new equipment shall be placed in operation until an inspection of such equipment has been made. When the required inspection shows that all equipment and safety devices are in good working condition and good repair, it shall be the duty of the Village Manager or designee to cause to be issued a certificate setting forth the result of such inspection and tests and containing the date of inspection, the weight which such equipment will safely carry, and a statement that all equipment complies with the applicable provisions of the code. It shall be the duty of the Village Manager or designee to order that all equipment found to be in an unsafe condition be stopped and remain inoperative until equipment is found to be in compliance with all provisions of this code.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: Code of Ordinances: Supplement 205 | Zoning: Supplement 89).

Full Breakdown

Section 22-33(46) through (49) of the Skokie Village Code amends the 2021 International Building Code to add the Village's own elevator safety chapter. 1 makes it unlawful to install or alter an elevator, dumbwaiter, escalator or lifting mechanism for a stage, orchestra floor or platform without first obtaining a Village permit supported by drawings and specifications. 2 requires every elevator, movable stage, movable orchestra floor, movable platform, dumbwaiter or escalator to be inspected under the direction of the Village Manager or designee at least once every six months, and bars any new equipment from operating until it has passed an initial inspection.

3 requires that certificate to be framed and posted in a conspicuous place in each elevator and near every dumbwaiter, movable stage, orchestra floor, platform lift or escalator. If an inspection instead finds equipment unsafe, the Village Manager or designee must order it stopped and kept inoperative until it is brought back into compliance. 1 in buildings four stories or taller, with a limited exemption for four-to-seven story buildings that installed an approved fire alarm and central-station notification system before January 1, 2010.

Violations & Fines

Operating an elevator or related lifting equipment without the required Village permit, or continuing to run equipment an inspector has ordered stopped as unsafe, violates Section 22-33 and is enforced under the general penalty in Section 1-6; equipment found out of compliance must remain inoperative until it passes a follow-up inspection.

Frequently Asked Questions

How often must elevators be inspected in Skokie?
Section 3001.5.2 of the amended building code requires every elevator, dumbwaiter, escalator, movable stage and movable orchestra floor in the Village to be inspected under the direction of the Village Manager or designee at least once every six months, in addition to an initial inspection before any new equipment goes into service.
What happens if an elevator fails inspection?
The Village Manager or designee must order any equipment found in an unsafe condition stopped and kept inoperative until a follow-up inspection confirms it complies with the code; the inspection certificate itself must list the date of inspection and the safe carrying weight.
Do older elevators get grandfathered out of safety upgrades?
Not entirely. Section 3009.1 requires elevators operating since January 3, 2005 to meet ASME A17.3 standards for standby lighting, telephone and alarm bells, and Section 3009.2 requires firefighters' elevator recall in buildings four stories or taller, though a narrow pre-2010 alarm-system exemption applies to four-to-seven story buildings.

Sources & Official References

Other rules in Skokie

All Skokie rules

Compare Skokie to another location·View the Illinois building safety overview

Get notified when Elevator Maintenance in Skokie, IL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Elevator Maintenance in Nearby Cities

How other cities in Cook County handle elevator maintenance.

Oak Lawn, IL
Some Restrictions
Oak Park, IL
Some Restrictions
Chicago, IL
Some Restrictions
Schaumburg, IL
Some Restrictions
Tinley Park, IL
Some Restrictions