Skip to main content
CityRuleLookup

Yorba Linda, CA Building Safety: Elevator Maintenance (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Governing standard
ASME A17.1, Safety Code for Elevators and Escalators
Adopted at
local IPMC amendment, § 15.34.070, Section 606.1
Covers
elevators, escalators and dumbwaiters in occupied buildings
Enforcement path
Building Official notice of violation, Section 107
Default penalty
up to $1,000 fine and/or 6 months custody
Continuing violation
each day counted as separate offense

Summary

The City of Yorba Linda's local Property Maintenance Code amendment at Yorba Linda Municipal Code § 15.34.070, Section 606.1, requires every elevator, escalator and dumbwaiter in an occupied building to be maintained in compliance with ASME A17.1, the national safety code for elevators. No dedicated inspection schedule appears in the local text; the standard governs upkeep.

§ 1.12.010. General penalty—Penalty for Code violations. A. Except as provided for in subsection B ... the violation of any such provisions of this Code or any other ordinance or any such rule, regulations or order shall be punished by a fine not exceeding $1,000.00 or imprisonment for a term not exceeding six months, or by both such fine and imprisonment, ... C. ... Every day any violation of this Code or any other ordinance of the city or such rule, regulation or order shall continue shall constitute a separate offense. ... § 15.34.070. Chapter 6 Mechanical and Electrical Requirements, amended. ... Section 606 Elevators, Escalators and Dumbwaiters, is hereby amended to read as follows: 606.1 General. Elevators, Escalators and Dumbwaiters, shall be maintained in compliance with ASME A17.1.

Full Breakdown

Section 15.34.070 is the City's local amendment to Chapter 6 of the International Property Maintenance Code, and it adds Section 606 for Elevators, Escalators and Dumbwaiters. Section 606.1 states in full that elevators, escalators and dumbwaiters shall be maintained in compliance with ASME A17.1, the American Society of Mechanical Engineers' Safety Code for Elevators and Escalators, incorporating that national standard's maintenance, testing and safety-device requirements by reference into the local Property Maintenance Code rather than writing separate local mechanical specifications. The same amended chapter requires related mechanical and electrical systems in the same building to stay code compliant: Section 604.1 requires every occupied building's electrical system to comply with the City's adopted California Building Codes, and Section 604.3.1.1 requires electrical distribution equipment exposed to water, tampering or physical damage to be replaced under the current California Electrical Code as the City has adopted and amended it.

Because Chapter 15.34 carries a single administrative framework across all of its Property Maintenance Code amendments, a failed or unmaintained elevator, escalator or dumbwaiter is treated the same as any other unsafe building component: the Building Official can act under Section 107, as amended at § 15.34.020, to serve a notice of violation ordering the owner to bring the equipment back into ASME A17.1 compliance, and Section 109 authorizes the code official to declare an unsafe elevator an unlawful structure or equipment subject to repair, restoration or removal from service until it is restored to a safe condition.

Violations & Fines

Failing to maintain an elevator, escalator or dumbwaiter in compliance with ASME A17.1 exposes a building owner to a Building Official notice of violation and correction order under Section 107, and the citywide general penalty at Yorba Linda Municipal Code § 1.12.010 applies in the absence of a chapter-specific fine: up to a $1,000 fine, up to six months in custody, or both, with the City also entitled to pursue civil remedies including injunction, and every day the equipment remains out of compliance treated as a separate offense.

Frequently Asked Questions

What maintenance standard applies to elevators in Yorba Linda buildings?
Section 606.1 of the City's Property Maintenance Code amendments, adopted at § 15.34.070, requires every elevator, escalator and dumbwaiter to be maintained in compliance with ASME A17.1, the national elevator and escalator safety code, rather than a separate locally written maintenance standard.
What happens if a building owner in Yorba Linda lets an elevator fall out of ASME compliance?
The Building Official can issue a notice of violation and order to correct under Section 107, and Section 109 lets the code official treat an unsafe elevator as an unlawful structure or equipment requiring repair, restoration or removal from service; unresolved violations fall back to the citywide general penalty of up to $1,000, six months in custody, or both.
Does Yorba Linda require a separate local inspection certificate for elevators?
The local amendment does not add its own inspection schedule; Section 606.1 simply ties compliance to ASME A17.1, so elevator maintenance, testing and inspection obligations flow from that national standard as incorporated into the City's Property Maintenance Code amendments.

Sources & Official References

Other rules in Yorba Linda

All Yorba Linda rules

California rules heatmap·Compare Yorba Linda to another location·View the California building safety overview

Get notified when Elevator Maintenance in Yorba Linda, CA changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.