Key Facts
- Governing code
- LMC § 16.12.120(C)
- Residential freeboard
- One foot above base flood elevation
- AO Zone standard
- One foot above FIRM depth number
- Nonresidential option
- Floodproof to watertight standard
- Enclosure openings
- 1 sq in per sq ft, min. 2 openings
- Certification required
- Registered engineer or surveyor
Summary
Livermore Municipal Code § 16.12.120(C) requires new residential construction and substantial improvements in special flood hazard areas to have the lowest floor elevated to one foot above the base flood elevation, with nonresidential structures allowed to floodproof instead.
Residential construction, new or substantial improvement shall have the lowest floor including basement: a. In an AO Zone, elevated above the highest adjacent grade to a height of one foot exceeding the depth number specified in feet on the FIRM, or elevated at least two feet above the highest adjacent grade if no depth number is specified; b. In an A Zone, elevated to one foot above the base flood elevation, as determined by the City; c. In all other zones, elevated to one foot above the base flood elevation.
Full Breakdown
090. For elevation, residential new construction or substantial improvement must have its lowest floor, including any basement, elevated to one foot above the base flood elevation in an A Zone or any other zone; in an AO Zone, the floor must sit one foot above the FIRM's specified flood depth number, or at least two feet above the highest adjacent grade if no depth number is given. 070. Once construction is complete, a registered professional engineer or surveyor must certify the lowest floor elevation on a FEMA elevation certificate, verified by the city building inspector and filed with the Community Development Director.
Nonresidential structures may instead be floodproofed below the required elevation so the structure is watertight, with structural components able to resist hydrostatic and hydrodynamic loads, certified by a registered engineer or architect. Fully enclosed areas below the lowest floor used only for parking, access or storage must allow floodwater to enter and exit automatically, either through engineer-certified design, an approved local floodproofing standard, or a minimum of two openings totaling at least one square inch of net area per square foot of enclosed area, with opening bottoms no higher than one foot above grade.
Detached garages and small accessory structures (limited to parking two cars or storage sheds under 150 square feet and $1,500 in value) may have floors below the BFE if flood-resistant materials are used below the BFE and mechanical equipment is elevated or floodproofed to one foot above the BFE.
Violations & Fines
A structure lacking the FEMA elevation certificate or engineer's floodproofing certification required by § 16.12.120(C) is presumed in violation of the chapter under the definition of "violation" in § 16.12.040, which triggers the misdemeanor penalty in § 16.12.080 until compliance documentation is provided to the Community Development Director.
Frequently Asked Questions
How high above base flood elevation must a new Livermore home be built?
Can a Livermore business floodproof instead of elevating?
Who certifies the elevation of a new structure's lowest floor in Livermore?
Sources & Official References
Other rules in Livermore
California rules heatmap·Compare Livermore to another location·View the California environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in Alameda County handle flood elevation requirements.