Skip to main content
CityRuleLookup

Jupiter, FL Trash & Recycling: Recycling Requirements (2026)

Some Restrictions
Compiled from the official code textEditor Martyn O'NeillLast verified September 2026

Key Facts

Multifamily threshold
10+ units triggers requirement
Storage area (10-30 units)
40 square feet minimum
Storage area (100-159 units)
160 square feet minimum
Setback from residential
25 feet minimum
Commercial recycling goal
50 percent of waste stream
Existing building exemption
Weekly curbside service required

Summary

Jupiter requires on-site recyclable material collection and storage areas at every multifamily development with ten or more units and at all new commercial developments under Town Code §§ 16-71 and 16-73. The areas must meet minimum floor-area, screening, setback and access standards enforced through town site plan review.

Recyclable material collection and storage areas shall be provided on-site at all multifamily developments with ten or more units, in accordance with the following requirements and/or standards: ... (5)Setback. The minimum setback for recyclable material collection and storage areas that are located on the exterior of buildings shall be 25 feet from residential districts or residential properties. ... Recyclable material collection and storage ... shall be provided on the site of all commercial developments for which an application for development order is filed after the effective date of the ordinance from which this article is derived, in accordance with the following standards: (1)Storage area. At least one recyclable material collection and storage area shall be provided for each new commercial development. The area shall be readily accessible and sized to meet a recycling goal of 50 percent for the type of commercial business operations within the commercial development.

Full Breakdown

Article III of Chapter 16 sets minimum recyclable material space standards for multifamily and commercial development. Section 16-71 requires collection and storage areas at 'all multifamily developments with ten or more units,' sized on a sliding scale: 40 square feet for 10-30 units, 100 square feet for 31-99 units, 160 square feet for 100-159 units, 240 square feet for 160-240 units, and 240 square feet plus one square foot per unit above 240. Exterior storage areas must sit at least 25 feet from residential districts or residential properties and be screened by a solid opaque enclosure of brick, concrete, concrete block or comparable masonry, wood or steel, with a metal gate and 24-inch shrubs spaced 24 inches on center.

Access must be designed so pickup trucks are not required to make unnecessary turning or backing movements. Multifamily buildings that already existed when the 1998 ordinance took effect are exempt if they receive curbside recycling service at least weekly under § 16-71(7). Commercial developments filing for a development order face a parallel standard under § 16-73: at least one storage area sized to meet 'a recycling goal of 50 percent' for the type of business operations, with the same 25-foot setback and screening rules. Applicants at either use type may substitute an alternative recycling plan if the town and its franchise hauler approve it.

Existing multifamily and commercial properties that retrofit to add these facilities may convert existing parking spaces to do so, subject to town staff review under §§ 16-72 and 16-74, with the town council weighing in only if the conversion substantially alters a previously approved site plan. All plans, new or retrofit, are reviewed by town staff under § 16-75.

Violations & Fines

Noncompliance with Article III's storage, screening or setback standards is enforced as a Chapter 16 violation under § 16-2: each day the deficiency continues is a separate offense. Penalties follow § 1-14's general civil penalty, including code enforcement action under Chapter 8, recovery of the town's attorney's fees and costs of prosecution, and a lien against the property for unpaid fines.

Frequently Asked Questions

Does my Jupiter condo building need a recycling storage area?
Only if it has ten or more units and was built after the town's 1998 ordinance, per § 16-71. Older qualifying buildings are exempt if they already receive curbside recycling collection at least weekly; newer or non-qualifying buildings must provide screened storage sized to the unit-count table in the code.
How big must a commercial recycling storage area be in Jupiter?
Section 16-73 does not set a flat square footage. It requires the area to be sized to meet 'a recycling goal of 50 percent' for that type of business, with supporting documentation submitted for town review, plus the same 25-foot residential setback and screening standards used for multifamily sites.
Can a Jupiter property use its own recycling plan instead of the code's standards?
Yes. Both §§ 16-71(6) and 16-73(4) let an applicant submit an alternative recyclable materials collection and storage plan; if the town and its franchise hauler approve it, the alternative replaces the article's standard storage, screening and setback requirements.

Sources & Official References

Other rules in Jupiter

All Jupiter rules

Florida rules heatmap·Compare Jupiter to another location·View the Florida trash & recycling overview

Get notified when Recycling Requirements in Jupiter, FL changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.

Recycling Requirements in Nearby Cities

How other cities in Palm Beach County handle recycling requirements.

Boynton Beach, FL
Some Restrictions
Boca Raton, FL
Some Restrictions
West Palm Beach, FL
Some Restrictions