Key Facts

Freeboard margin
One foot (1') above base flood elevation
Definitions citation
Caldwell City Code § 12-15-03
Elevation standard
Caldwell City Code § 12-15-09(2)A
Administering officer
City Floodplain Administrator
Adopted by
Ordinance 3207, March 4, 2019
No-data zone floor
2 feet above highest adjacent grade

Summary

Caldwell's floodplain ordinance requires new residential construction in a mapped special flood hazard area to elevate its lowest floor, including any basement, no lower than the flood protection elevation, which equals the FEMA base flood elevation plus a one-foot freeboard margin. The Floodplain Administrator enforces the standard under Caldwell City Code § 12-15-09.

FREEBOARD: ... A factor of safety usually expressed in feet above a flood level for the purposes of floodplain management. ... The base flood elevation (BFE) plus the freeboard establishes the flood protection elevation (FPE). Freeboard shall be one foot (1'). ... ... A. Residential Construction: New construction, substantial improvements, and development of any residential structure (including manufactured homes) shall have the lowest floor, including basement, elevated no lower than the flood protection elevation, as defined in section 12-15-03 of this article.

View official code

Official source re-checked September 7, 2026: no newer edition of the code had been published (publisher’s edition: 2026 Code: Local legislation current through Ordinance 3747, passed 3-16-2026).

Full Breakdown

Caldwell's flood damage prevention ordinance defines Base Flood Elevation (BFE) at Caldwell City Code § 12-15-03 as the water-surface elevation of the flood having a one percent chance of being equaled or exceeded in any given year, determined by FEMA or FEMA-approved engineering studies. " Combined, BFE plus freeboard sets the Flood Protection Elevation (FPE) that governs construction. Under the specific standards at Caldwell City Code § 12-15-09(2)A, new construction, substantial improvements and development of any residential structure, including manufactured homes, located in a special flood hazard area where BFE data has been provided must have its lowest floor, including any basement, elevated no lower than the flood protection elevation.

Non-residential structures face the identical elevation floor under subsection (2)B, though they may floodproof to that elevation instead of physically raising the building, certified by a registered professional engineer or architect. Manufactured homes under subsection (2)C must have their lowest floor at or above the FPE and be anchored to resist flotation and lateral movement. Where no FEMA base flood elevation data exists for a Zone A area, subsection (3)D requires the lowest floor to be elevated or floodproofed to at least two feet above the highest adjacent grade.

Compliance is verified through an elevation certificate submitted to the Floodplain Administrator, who administers the article under Caldwell City Code § 12-15-07, including issuing floodplain development permits before construction begins. The article was adopted by Ordinance 3207 on March 4, 2019.

Violations & Fines

Building below the required flood protection elevation without an approved floodplain development permit and elevation certificate violates Caldwell City Code § 12-15-09. General code violations carry the citywide penalty at Caldwell City Code § 01-01-05: a fine and/or imprisonment up to the maximum set by Idaho Code § 50-302, with continuing noncompliance charged as a separate offense each day, in addition to any FEMA flood-insurance rating consequences.

Frequently Asked Questions

How high above the base flood elevation must a new Caldwell home be built?
At least one foot. Caldwell City Code § 12-15-03 defines freeboard as one foot above the base flood elevation, and § 12-15-09(2)A requires new residential construction's lowest floor, including any basement, to sit no lower than that combined flood protection elevation.
Does a Caldwell business have to physically raise its building in a flood zone?
Not necessarily. Under Caldwell City Code § 12-15-09(2)B, non-residential structures may be floodproofed to the flood protection elevation instead of elevated, provided a registered professional engineer or architect certifies the design is watertight and can resist hydrostatic and hydrodynamic loads.
What if FEMA hasn't mapped a base flood elevation for my Caldwell lot?
Caldwell City Code § 12-15-09(3)D sets a fallback: without FEMA base flood elevation data, the lowest floor must still be elevated or floodproofed to at least two feet above the highest adjacent grade at the building site.

Sources & Official References

Other rules in Caldwell

All Caldwell rules

Compare Caldwell to another location·View the Idaho environmental rules overview

Get notified when Flood Elevation Requirements in Caldwell, ID changes

We'll email you the moment we detect a change in the code. No spam, unsubscribe anytime.

We'll never sell or share your email. One-click unsubscribe in every email.

See something wrong?

Help us keep this page accurate. If you notice an error or outdated information, let us know.