Key Facts
- Manufactured home elevation
- At/above base flood elevation, or piers 36 in.
- Accessory structure cap below BFE
- 600 sq. ft., one story
- Substantial improvement trigger
- 50% of market value in 10 years
- Baseline period
- Since January 1, 2023
- Elevation certification
- By licensed surveyor or civil engineer
Summary
In Alameda County flood hazard areas, Dublin requires manufactured homes, accessory structures, and substantially improved buildings to have their lowest floor at or above the base flood elevation shown on the FEMA maps, under Municipal Code §§ 7.24.370, 7.24.380 and 7.24.190.
Manufactured homes that are placed, replaced, or substantially improved on sites located in an existing manufactured home park or subdivision, unless on a site where substantial damage as a result of flooding has occurred, shall be elevated such that either the: A. Lowest floor, or bottom of the lowest horizontal structural member, as applicable to the flood hazard area, is at or above the base flood elevation. B. Bottom of the frame is supported by reinforced piers or other foundation elements of at least equivalent strength that are not less than thirty-six (36) inches in height above grade.
Official source re-checked September 8, 2026: no newer edition of the code had been published (publisher’s edition: current through Ordinance 2-26, passed March 3, 2026).
Full Breakdown
370 requires manufactured homes placed, replaced, or substantially improved on sites in an existing manufactured home park or subdivision to be elevated so that either the lowest floor, or the bottom of the lowest horizontal structural member, is at or above the base flood elevation, or alternatively so the bottom of the frame rests on reinforced piers or equivalent foundation elements at least thirty-six inches high above grade. 380 replaces the state Appendix G rule for detached garages and accessory storage structures used only for parking or storage: they may sit below the base flood elevation only if they are one story, no larger than 600 square feet, anchored against flotation and lateral movement, built with flood openings meeting the building code, constructed of flood damage-resistant materials below the base flood elevation, and have mechanical, plumbing and electrical systems elevated to or above the base flood elevation.
320 sets the trigger at cumulative work costing fifty percent or more of the structure's market value within a rolling ten-year period beginning with the first permitted improvement after January 1, 2023. Once work crosses that threshold, or the structure has suffered substantial flood damage, compliance with the base flood elevation standard is mandatory regardless of the actual repair scope. 120.
Violations & Fines
A building lacking documentation of its lowest-floor elevation is presumed in violation under § 7.24.280 until the required certification is filed, and that violation is a misdemeanor. The Floodplain Administrator can issue a stop-work order or notice of violation under § 7.24.290, and anyone who keeps working after being served with one faces the penalties set in Chapters 1.04 and 1.06 under § 7.24.300.
Frequently Asked Questions
How high above the flood zone must a manufactured home be set in Dublin?
Can I build a garage below the base flood elevation in a Dublin flood zone?
When does a remodel have to meet Dublin's flood elevation standards?
Sources & Official References
Other rules in Dublin
California rules heatmap·Compare Dublin to another location·View the California environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.
Flood Elevation Requirements in Nearby Cities
How other cities in Alameda County handle flood elevation requirements.