Eagan, MN Environmental Rules: Flood Elevation Requirements (2026)
Key Facts
- Freeboard requirement
- 2 feet above regulatory flood protection elevation
- Regulatory flood protection elevation
- 1 foot above the regional flood profile
- Fill extension
- 15 feet beyond structure at same elevation
- Basements
- Prohibited below 2-foot freeboard line
- Certification
- Registered engineer, architect, or surveyor required
Summary
Eagan requires structures in the Flood Fringe District to sit at least two feet above the "regulatory flood protection elevation," itself defined as one foot above the regional flood profile, under City Code § 11.66. That stacks to roughly three feet of freeboard above the 100-year flood elevation before a certified elevation survey can close out the building permit.
Regulatory flood protection elevation means a point not less than one foot above the water surface profile associated with the regional flood plus any increases in the flood heights attributable to encroachments on the floodplain that result from designation of a floodway. It is the elevation to which uses regulated by this section are required to be elevated or floodproofed. ... G.Standards for flood fringe district permitted uses:1.All structures, including accessory structures, shall be such that the lowest floor of the lowest enclosed area (including basement and crawl space) is no less than two feet above the regulatory flood protection elevation (100-year flood elevation). If fill is placed to increase the grade elevation, the finished fill elevation for a structure shall extend at the same elevation at least 15 feet beyond the outside limits of the structure erected thereon.
Full Breakdown
City Code § 11.66, Subd. 2 defines "regulatory flood protection elevation" as a point not less than one foot above the water surface profile associated with the regional (100-year) flood, plus any increase in flood heights caused by floodway encroachments; it is the elevation to which regulated uses must be elevated or floodproofed. Building on that base, Subd. 5.G.1 requires every structure in the Flood Fringe District, including accessory structures, to have the lowest floor of its lowest enclosed area, basement or crawl space included, no less than two feet above that regulatory flood protection elevation.
When fill is used to reach that height, the finished fill must extend at the same elevation at least 15 feet beyond the structure's outside walls, so the pad cannot simply taper down at the foundation line. Subd. 5.I lets a builder use stilts, pilings, or an above-grade enclosed area such as a crawl space or tuck-under garage instead of fill, but the design must be certified by a registered professional engineer or architect as meeting the state building code, and enclosed areas below the freeboard line need automatic flood-venting openings sized to one square inch per square foot of enclosed area.
Residential basements are banned outright if any part sits less than two feet above the regulatory flood protection elevation under Subd. 5.I.2. Before the city signs off, § 11.66, Subd. 12.C requires certification by a registered engineer, architect, or land surveyor that the finished fill and building elevations were actually built as approved, and the community development director keeps that elevation record on file.
Violations & Fines
Building below the required two-foot freeboard, or filling without extending the pad 15 feet beyond the structure as § 11.66, Subd. 5.G.1 demands, violates the floodplain overlay district; § 11.99 makes any chapter 11 zoning violation a misdemeanor, and the city can withhold or revoke the certificate of zoning compliance until an engineer certifies compliance.
Frequently Asked Questions
How high above flood level must a house be built in Eagan?
Can I use fill to raise my house above the flood line?
Is a basement allowed in Eagan's flood fringe?
Sources & Official References
Other rules in Eagan
Compare Eagan to another location·View the Minnesota environmental rules overview
See something wrong?
Help us keep this page accurate. If you notice an error or outdated information, let us know.